Sludge Dewatering Press

Sludge Thickener

p_gs_blog

Sludge Dewatering Press

GS Series

Raw Wastewater /Waste Activated Sludge /
Chemically Precipitated Sludge
Mixed Raw Sludge
Sludge Concentration (TS) -1.50% 3.00%
GS-101 up to 10 lb-DS/h up to 43 lb-DS/h
GS-131 up to 20 lb-DS/h up to 86 lb-DS/h
GS-132 up to 40 lb-DS/h up to 173 lb-DS/h
GS-201 up to 44 lb-DS/h up to 193 lb-DS/h
GS-202 up to 88 lb-DS/h up to 386 lb-DS/h
GS-301 up to 100 lb-DS/h up to 433 lb-DS/h
GS-302 up to 200 lb-DS/h up to 866 lb-DS/h
GS-303 up to 300 lb-DS/h up to 1300 lb-DS/h
GS-351 up to 200 lb-DS/h up to 866 lb-DS/h
GS-352 up to 400 lb-DS/h up to 1733 lb-DS/h
GS-353 up to 600 lb-DS/h up to 2600 lb-DS/h
GS-354 up to 800 lb-DS/h up to 3466 lb-DS/h
Model Dimensions (inch) Total Power
Consumption (kW)
Weight (lb)
L W H Empty Operation
GS-101 74.8 43.5 56.6 0.4 727 1168
GS-131 80.5 43.5 56.6 0.4 749 1190
GS-132 80.5 44.6 56.6 0.5 859 1322
GS-201 97.8 43.5 56.6 0.5 1102 1587
GS-202 124.6 57.6 73.0 1.35 2777 4155
GS-301 148.2 55.7 73.0 1.35 2733 4166
GS-302 156.8 66.9 73.0 1.75 3913 6117
GS-303 163.9 78.7 73.0 2.15 4850 7672
GS-351 177.1 64.3 88.5 2.45 4706 6845
GS-352 203.9 75.1 88.7 5.95 9038 14837
GS-353 213.7 90.9 88.7 7.45 11177 20326
GS-354 219.6 112.5 88.7 8.95 14616 23589
* Throughput above is calculated as approximate and may vary depending on sludge condition. For model selection, please contact us.
* Throughput of each model is based on sludge cake with 20±5% solids content.
* There is no certain upper limitation on inlet sludge concentration, however, the target sludge must be flowable.
* Throughput of Mixed Sludge (Primary Sludge and Waste Activated Sludge) is based on sludge containing 20% fiber(150 micron mesh clearance) against Total Solids.
p_ec_blog1

Sludge Dewatering Press

EC Series

Raw Wastewater /
Waste Activated Sludge /
Chemically Precipitated Sludge
Mixed Raw Sludge
Sludge
Concentration
(TS)
-1.5% 3.0%
EC-101 up to 10 lb-DS/h up to 20 lb-DS/h
EC-102 up to 20 lb-DS/h up to 40 lb-DS/h
EC-131 up to 35 lb-DS/h up to 70 lb-DS/h
EC-132 up to 70 lb-DS/h up to 140 lb-DS/h
EC-133 up to 105 lb-DS/h up to 210 lb-DS/h
EC-202 up to 60 lb-DS/h up to 120 lb-DS/h
EC-203 up to 90 lb-DS/h up to 180 lb-DS/h
EC-204 up to 120 lb-DS/h up to 240 lb-DS/h
EC-205 up to 150 lb-DS/h up to 300 lb-DS/h
Model Dimensions (inch) Total Power
Consumption (kW)
Weight (lb)
L W H Empty Operation
EC-101 69.1 27.5 60.6 0.65 551 1433
EC-102 69.1 35.4 60.6 0.7 661 1763
EC-131 69.1 27.5 60.6 0.7 584 1466
EC-132 69.1 35.4 60.6 0.8 727 1829
EC-133 72.7 43.3 60.6 0.9 881 2314
EC-202 97.8 46.4 68.0 1.45 1873 3968
EC-203 102.0 57.8 68.0 1.8 2325 5191
EC-204 104.9 70.0 68.0 2.7 3196 6834
EC-205 107.9 82.0 68.0 2.9 3968 8157

* Throughput above is calculated as approximate and may vary depending on sludge condition.

For model selection, please contact us.

* Throughput of each model is based on sludge cake with solid content higher than 15%.

* There is no certain upper limitation on inlet sludge concentration, however, the target sludge must be flowable.

* Throughput of Mixed Sludge (Primary Sludge and Waste Activated Sludge) based on sludge containing 20% fiber(150 micron mesh clearance) against Total Solids.

p_es_blog

Sludge Dewatering Press

ES-051

Raw Wastewater /
Waste Activated Sludge /
Chemically Precipitated Sludge
Mixed Raw Sludge
Sludge
Concentration
(TS)
-1.5% 3.0%
ES-051 up to 5 lb-DS/h up to 10 lb-DS/h
Model Dimensions (inch) Total Power
Consumption (kW)
Weight (lb)
L W H Empty Operation
ES-051 43.1 29.4 43.3 0.2 352 396

* Throughput above is calculated as approximate and may vary depending on sludge condition.

For model selection, please contact us.

* Throughput of each model is based on sludge cake with solid content higher than 15%.

* There is no certain upper limitation on inlet sludge concentration, however, the target sludge must be flowable.

* Throughput of Mixed Sludge (Primary Sludge and Waste Activated Sludge) is based on sludge containing 20% fiber(150 micron mesh clearance) against Total Solids.

p_vt_blog

Sludge Thickener

VT Series

Model Capacity (inflow)
GPH
Dimensions (inch) Total Power
Consumption (kW)
Weight (lb)
L W H Empty Operation
VT-101 up to 270 69.7 35.4 49.2 0.3 352 639
VT-131 up to 800 69.7 35.4 49.2 0.3 374 661
VT-201 up to 2,640 95.9 35.4 68.3 1.15 793 1499
VT-301 up to 8,000 136.3 51.9 79.7 1.5 1851 3637
VT-302 up to 16,000 188.1 66.3 79.7 3 3306 9259
VT-303 up to 24,000 195.9 75.9 79.7 4.45 4299 12235
* Capacity is based on waste activated sludge from biological treatment with TS 0.4% and thickening up to 4% with polymer.
* Figures above are calculated as approximate and may vary depending on sludge condition. For model selection, please contact us.

Feel free to contact us for any inquiries
about sludge treatment and wastewater treatment.

Inquiries about Products, operation instructions, troubleshooting and repairs

  • Sludge Dewatering Press & Thickener
  • Sludge dryer & sludge dewatering and fermentation system
  • Water Treatment Chemicals
  • Other Products

Inquiry by Phone

+81-45-540-8580

Weekdays 9:00~17:00

top